ESE Permit Verification

Mode: Ready

A) Permit Details

Required.
Used for hazard-driven prompts.
NameRankTime InTime Out
Rule: minimum two persons entering + one attendant at entrance (single-person entry not permitted — MSC 3.11).
Rule: max validity ≤ 8 hours (MSC 5.2).
B) Controls Confirmations
C) Atmosphere Testing (pre-entry + while occupied)
MSC 7.6: Stop ventilation ~10 min before testing.
Rule: test-to-entry ≤ 30 minutes.
Rule: < 1% (MSC 7.4.3).
MSC 7.4.2: CO₂ < 5,000 ppm (0.5%vol).
MSC 7.4.4: < 50% OEL.
Multi-level sampling (Upper / Mid / Lower) — recommended
MSC 7.2: test at several levels/areas to account for gas stratification.
LevelO₂%LELCO₂CO (% OEL)
Upper
Mid
Lower
Gas% of OELNotes
Default max: 30 min (use shorter interval if RA requires).
MSC 8.3: re-test after breaks and before re-entry.

While occupied — Repeat Tests Log

TimeO₂%LELCO₂CO (% OEL)Note
Work Breaks (optional)
Out TimeIn Time
D) Close-Out

Register Preview

ID

Cargo prompts

    Validation results

    No validation run yet.
    Hover items or fields to see details.